English (United States) Tiếng Việt (Việt Nam)

 

I always have so much fun with georgetown dc escorts Hire us and you will experience the best san diego private dancers Ever met a stripper in las vegas ? We sure have they are nasty south beach escorts in the city
  
Login

 

  
Product > DC Drives  > Mentor MP

 

Product

Mentor MP - High performance DC drive solution platform

25 to 7,400A (5 to 6,500hp)

208 - 460V / 575V / 690V

Mentor MP brings DC drive technology up to date, enabling existing and new DC motors to provide economic and productive service. DC drive technology remains cost effective, efficient and is relatively simple to implement. For new applications, DC provides many advantages, especially for regenerative and high-power applications.

 

Features
Specifications
Options
Software
Downloads

·         Models available for two or four quadrant (regenerative) operation

·         25A to 7400A, 24V - 480V / 500V - 575V / 500V - 690V

·         Optional high-brightness LED or multi-language LCD keypad, simple configuration using plain text

·         Modular parallel connection for higher power motor operation

·         12/24 pulse operation to minimize harmonics

·         IP20 (NEMA 1) protection for size 1, IP10 (open chassis) for size 2A and 2B, and IP00 (open chassis) for size 2C and 2D for easy, low cost installation

·         Integrated drive and motor protection for:

·         Over current

·         Over temperature

·         Phase loss

·         SCR/Thyristor junction temperature

·         Feedback loss

·         Field loss

·         Armature open circuit

·         Internal field controller with intelligent field weakening means that for 90% of applications no additional external controller is required

·         Frame size 1 to 8A

·         Frame size 2 to 20A

·         Flux control for enhanced open loop performance

·         Optional FXMP25 external field controller for current fields up to 25A

·         Digital link for field control from Mentor MP or Mentor II

·         Standalone digital control mode for simple application

·         Flux control for enhanced open loop performance

·         Intelligent field weakening

·         Field forcing – for high dynamic machine reversal

·         Field reversal – low dynamic machine reversing using two quadrant main stack

·         Mentor MP size 1 can be used for fields greater than 25A

·         Serial port for Modbus RTU and PC communications

·         3 Universal option module slots, allowing Mentor
MP to benefit from the solutions developed for Control Techniques market leading AC drive technology.
Each option slot allows:

·         High performance PLC and motion control

·         Ethernet and Fieldbus communications

·         Connectivity to additional feedback devices

·         Additional I/O

·         Galvanically isolated control

·         Smartcard for drive parameter back-up and copying, allowing rapid installation and maintenance

·         Integrated PLC as standard

·         Standard software features for easy integration

·         PID controller

·         Motorized potentiometer

·         Digital lock (Slave operation from master encoder)

·         Open loop control using estimated speed advanced processing based on armature voltage and field flux feedback

·         Closed loop control using

·         Tacho-generator feedback for connection to traditional DC motor

·         Incremental encoder feedback for higher accuracy and position control

·         Optional SinCos, SSI, Hiperface and EnDAT connectivity for high performance applications

·         High performance control strategy

·         32 bit microprocessor

·         35μs current sampling time

·         Speed controller and ramps update 250μs

·         Autotune features for armature, field current loops and speed loop

Current ratings

The power ratings for the 480V, 575V and 690V configurations are shown below.
The continuous current ratings given are for a maximum ambient temperature of 40°C (104°F) and an altitude of 1000m (3,300ft). For operation at higher temperatures and altitudes de-rating is required. Overload of 150% for 30s is available with ambient temperature of 40°C (104°F) up to a maximum of 10 repetitions per hour.

 

230V ratings

MODEL

AC INPUT CURRENT

DC OUTPUT CURRENT

TYPICAL MOTOR POWER

CONTINUOUS

CONTINUOUS

150% OVERLOAD

@240Vdc

A

A

A

HP

MP25A4(R)

22

25

37.5

5

MP45A4(R)

40

45

67.5

10

MP75A4(R)

67

75

112.5

20

MP105A4(R)

94

105

157.5

30

MP155A4(R)

139

155

232.5

40

MP210A4(R)

188

210

315

60

MP350A4(R)

313

350

525

100

MP420A4(R)

376

420

630

125

MP550A4(R)

492

550

825

150

MP700A4(R)

626

700

1050

200

MP825A4(R)

738

825

1237.5

225

MP900A4(R)

805

900

1350

250

MP1200A4(R)

1073

1200

1800

350

MP1850A4(R)

1655

1850

2775

550

480V ratings

MODEL

AC INPUT CURRENT

DC OUTPUT CURRENT

TYPICAL MOTOR POWER

CONTINUOUS

CONTINUOUS

150% OVERLOAD

@400Vdc

@ 500 Vdc

A

A

A

kW

HP

MP25A4(R)

22

25

37.5

9

15

MP45A4(R)

40

45

67.5

15

27

MP75A4(R)

67

75

112.5

27

45

MP105A4(R)

94

105

157.5

37.5

60

MP155A4(R)

139

155

232.5

56

90

MP210A4(R)

188

210

315

75

125

MP350A4(R)

313

350

525

125

200

MP420A4(R)

376

420

630

150

250

MP550A4(R)

492

550

825

200

300

MP700A4(R)

626

700

1050

250

400

MP825A4(R)

738

825

1237.5

300

500

MP900A4(R)

805

900

1350

340

550

MP1200A4(R)

1073

1200

1800

450

750

MP1850A4(R)

1655

1850

2775

700

1150

575V ratings  

MODEL

AC INPUT CURRENT

DC OUTPUT CURRENT

TYPICAL MOTOR POWER

CONTINUOUS

CONTINUOUS

150% OVERLOAD

@630Vdc

@ 600 Vdc

A

A

A

kW

HP

MP25A5(R)

22

25

37.5

14

15

MP45A5(R)

40

45

67.5

25

30

MP75A5(R)

67

75

112.5

42

50

MP105A5(R)

94

105

157.5

58

75

MP155A5(R)

139

155

232.5

88

100

MP210A5(R)

188

210

315

120

150

MP350A5(R)

313

350

525

195

250

MP470A5(R)

420

470*

705

265

350

MP700A5(R)

626

700

1050

395

500

MP825A5(R)

738

825*

1237.5

465

600

MP1200A5(R)

1073

1200

1800

680

900

MP1850A5(R)

1655

1850

2775

1045

1400

*For this rating at 575V, 150% overload time is 20s at 40°C and 30s at 35°C

 690V ratings

MODEL

AC INPUT CURRENT

DC OUTPUT CURRENT

TYPICAL MOTOR POWER

CONTINUOUS

CONTINUOUS

150% OVERLOAD

@760Vdc

@ 700 Vdc

A

A

A

kW

HP

MP350A6(R)

313

350

525

240

300

MP470A6(R)

420

470*

705

320

400

MP700A6(R)

626

700

1050

480

600

MP825A6(R)

738

825*

1237.5

650

700

MP1200A6(R)

1073

1200

1800

850

1000

MP1850A6(R)

1655

1850

2775

1300

1600

* For this rating at 690V, 150% overload time is 20s at 40°C  and 30s at 35°C .

 Inputs and Outputs 

FUNCTION

QTY

I/O DEFAULT FUNCTION

RATING

Analog input 1

1


Speed ref 1

± 10V

Analog input 2

 

1

Speed ref 2

± 10V(default), 0-20mA or 4-20mA

Analog input 3

1

Motor thermistor

± 10V, 0-20mA, 4-20mA or Motor thermistor input (default)

Analog output

2

Speed feedback output

Current feedback output

± 10V(default), 0-20mA or 4-20mA

Digital input

3

Run reverse input

Local/Remote select

Jog forward input

+24V

Digital input / output

3

At speed output

Reset input

Run forward input

+24V

Relay

2


Drive OK indicator

Normally closed

Drive enable

1


Drive enable

+24V

+24V External input

1


External 24V supply

+24V

Conformance

·         Humidity 95% maximum (non condensing) at 40°C (104°F)

·         Ambient temperature -15°C to +40°C (5°F to +104°F), 55°C (131°F) with derating

·         Altitude: 0 to 3000m (9,900ft), derate 1% per 100m between 1000m (3,300ft) and 3000m (9,900ft)

·         Vibration: Tested in accordance with IEC 60068-2-64

·         Mechanical shock tested in accordance with IEC 60068-2-29

·         Storage temperature -40°C to +70°C (-40°F to +158°F)

·         Electromagnetic immunity complies with EN 61800-3 and EN 61000-6-2

·         Notch Immunity to IEC60146-1-1 class A

·         IEC 61800-5-1 Electrical safety

·         IEC 61131-2 I/O

·         EN 60529 Ingress protection

·         UL508C

·         EN 61000-6-4 EMC - with optional EMC filters

·         RoHS compliant 

 

 

 

MODEL

FRAME

ARMATURE CURRENT

(A)*

FIELD

CURRENT (A)

OVERALL DIMENSION

QUADRANTS OF
OPERATION

480V

EN / IEC

cULus

575V

EN / IEC

cULus to 600V

690V

EN / IEC

Width
(W)

Height
(H)

Depth
(D)

MP25A4(R)

MP25A5(R)

 

1A

25*

8

293mm (11.54in)

444mm (17.48in)

222mm (8.74in)

2 and 4

MP45A4(R)

MP45A5(R)

45*

MP75A4(R)

MP75A5(R)

75*

MP105A4(R)

MP105A5(R)

 

1B

105*

293mm (11.54in)

444mm (17.48in)

251mm (9.88in)

2 and 4

MP155A4(R)

MP155A5(R)

 

155*

MP210A4(R)

MP210A5(R)

 

210*

MP350A4(R)

MP350A5(R)

MP350A6(R)

2A

350*

20

495mm (19.49in)

640mm (25.20in)

301mm (11.85in)

2 and 4

MP420A4(R)

 

 

420*

 

MP470A5(R)

MP470A6(R)

470**

MP550A4(R)

 

 

550*

MP700A4(R)

MP700A5(R)

MP700A6(R)

2B

700*

495mm (19.49in)

640mm (25.20in)

301mm (11.85in)

2 and 4

MP825A4(R)

MP825A5(R)

MP825A6(R)

825**

MP900A4(R)

 

 

900*

MP1200A4

MP1200A5

MP1200A6

2C

1200*

555mm (21.85in)

1050mm

(41.34in)***

611mm (24.06in)

2

MP1850A4

MP1850A5

MP1850A6

1850*

MP1200A4R

MP1200A5R

MP1200A6R

2D

1200*

555mm (21.85in)

1510mm (59.45in)***

611mm (24.06in)

4

MP1850A4R

MP1850A5R

MP1850A6R

1850*

*Current ratings are at 40°C with 150% overload for 30s. **For this rating at 575V and 690V, 150% overload time is 20s at 40°C and 30s at 35°C.
***Height including optional fit exhaust duct cover is 1252mm (49.29in) for size 2C and 1712mm (67.40in) for size 2D.

7400A is achieved by parallel connection of Mentor MP drives